New Mexico’s rule does not just say “disinfect the foot spa”: 16.34.7.9(A)(35) NMAC lists seven steps, in order, for every pedicure basin after every service, names the disinfectant by its label, and makes the pump run for the whole contact time. Here is the Board’s procedure in the rule’s order, what the rule says about liners, the three times it sets, and the five things that go in the log when each disinfection is done.

What the rule covers

Four numbered items in the Board’s infection-control standards for establishments, 16.34.7.9(A): (35), the after-service procedure for “filters and drains of pedicure basins” and the tub itself; (36), liners; (37), the three times (“between clients, at the end of the day, and deep disinfection once weekly”); and (38), the log. The same log sentence is repeated in the establishment license requirements, 16.34.7.8(H)(8). The rule was amended effective January 13, 2026, and the four items read as they did before. There is one written procedure, (35)’s, and three times it is done; the rule does not write a separate end-of-day or weekly procedure.

The disinfectant the rule names

(35) names it twice: the filters and drains are disinfected “with an EPA hospital grade disinfectant”, and the basin is filled with clean water and “an EPA-registered hospital level disinfectant is added following the manufacturer’s directions”. “Hospital grade” is the label claim, not a brand; the EPA registration number is on the label too. “Following the manufacturer’s directions” means mixed at the label’s strength and left for the label’s contact time, and (35)(f) makes the contact time the clock for the pump. The rule names no bleach step and no fixed number of minutes: the label decides.

New Mexico’s rule then asks for something no other state’s rule does: “the name of the disinfectant used” on every log entry, so the product’s name is written as often as the date is. (Washington’s state log form has a column for the product, but Washington’s rule asks only for the date and time.)

After each service ((35), every pedicure basin or tub)

(35): “filters and drains of pedicure basins must be cleaned and disinfected after each use with an EPA hospital grade disinfectant. Immediately after each service, the practitioner must follow steps listed below:”

  1. “dirty water is drained, and any visible debris is removed;” (a).
  2. “all removable filter screens, inlet jets, footplates, impeller assemblies, and other parts are removed and debris eliminated before scrubbing with a disinfected brush and detergent and water;” (b).
  3. “the tub basin is scrubbed with detergent and water, and rinsed with water, and drained;” (c).
  4. “removable parts are replaced;” (d).
  5. “the basin or tub is filled with clean water and an EPA-registered hospital level disinfectant is added following the manufacturer’s directions;” (e).
  6. “if the pedicure tub is electrical, the fan or pump must be turned on and the unit operated for the entire contact time; and” (f).
  7. “after the contact time is complete, the disinfectant must be drained, and the tub rinsed with clean water.” (g).
  8. Record it: date, time, After Each Client, the person’s legible signature and license number, and the disinfectant’s name.

The rule’s word is “immediately after each service”, and the contact time is the label’s, with the pump running the whole of it. Start the clock when the disinfectant is in the water at label strength and the pump is on, not when you start scrubbing. On a basin with no pump, step 6 does not apply and the disinfectant stands for the label’s time instead.

At the end of the day, and once a week

(37) sets the other two times: “pedicure basins shall be disinfected between clients, at the end of the day, and deep disinfection once weekly”. It writes no steps for either. The procedure the rule writes is the one above; the end-of-day disinfection and the weekly “deep disinfection” are named and not described, and the disinfectant’s label is what the rule points to for the rest (“following the manufacturer’s directions”). Do not borrow another state’s end-of-day or weekly steps and present them as New Mexico’s. Each is its own row in the log, End of Day or Weekly; on the weekly night ReadyPedi records the End of Day row and then the Weekly row. Our guide to how often to clean a pedicure foot spa in New Mexico covers the schedule and how the weekly interval is counted.

Liners

(36): “pedicure tub liners are single use items and must be disposed of immediately after use”. That is the rule’s whole treatment of liners. It does not say the basin under a liner skips the after-service procedure; (37) says pedicure basins are disinfected between clients, with no exception. So a liner is thrown away after the service and the basin is disinfected and logged as any other. ReadyPedi has no liner kind for New Mexico for that reason: set the chair as the basin it is.

Writing it down

Each disinfection above ends in the same sentence of the rule:

a log is maintained by the salon showing the legible signature, license number of the person disinfecting the tub, the time and date of the disinfection process and the name of the disinfectant used. Log entries must be maintained on the salon premises for 12 months.

Five fields per entry: the legible signature, the license number, the time, the date, the disinfectant’s name. Name the disinfection (After Each Client, End of Day, Weekly) and the tub as well, or the log cannot show which of the three was done on which unit. One sheet per tub; one row per disinfection; on the weekly night, an End of Day row and then a Weekly row. There is no not-used row and no out-of-service notation in New Mexico’s rule. Our guide to the printable New Mexico pedicure cleaning log covers the log column by column and offers a blank, and the New Mexico page has the rule next to the app.

What to keep at the chair

A disinfected brush and detergent for the scrub (the rule says “a disinfected brush”). The hospital-grade disinfectant mixed at label strength, with its label where an inspector can read it: the log names the product on every row, and the label is what proves it is EPA-registered and hospital grade. A timer for the label’s contact time, because the pump runs the whole of it. The tub’s log or the tablet that holds it, with every technician’s license number on the roster, since the rule puts it beside every entry. ReadyPedi’s three taps at the chair log each disinfection with the time it was finished, the tech’s name and license number, and the shop’s disinfectant, and print the record for any tub and month. A shop can start free today.

Frequently asked questions

How long does the disinfectant have to work?

For the time its label says. The rule names no number of minutes; it says the disinfectant is added “following the manufacturer’s directions” and, on an electrical tub, the pump or fan runs “for the entire contact time”.

Can I use bleach in a New Mexico pedicure tub?

The rule names “an EPA hospital grade disinfectant” and “an EPA-registered hospital level disinfectant”, used per its label, and names no bleach step. Read the product’s label against those words; the label, not the chemistry, is what the inspector reads, and the product’s name goes on every log entry.

Does the rule say how to do the end-of-day or weekly disinfection?

No. It sets the three times and writes one procedure, the after-service one. Follow your disinfectant’s label for the rest, and record each as its own row.

Do I disinfect a basin after a disposable liner?

The rule says liners are single use and thrown away immediately after use, and it says pedicure basins are disinfected between clients, with no exception for a lined one. Discard the liner, run the after-service procedure on the basin, and log it.

What if a step was missed?

The log is a record of what was done, not of what should have been. If a disinfection was missed, do it now and write the real time. A log that says every disinfection ended at 9:00 pm every night in the same handwriting is the thing that fails an inspection.

This guide explains New Mexico’s pedicure tub disinfection procedure in plain language and is not legal advice. The New Mexico Board of Barbers and Cosmetologists’ rules are the authority on New Mexico pedicure equipment disinfection and recordkeeping requirements.